{"product_id":"kl-40mpcg","title":"KL-40MPCG - K-LOK 400 A Male Connector Protective Cap, Green","description":"\u003c!-- Combined Shopify product HTML for KL-40MPCG --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #2C3E50 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #2C3E50 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-40MPCG\" data-color=\"Green\"\u003e\n  \u003ch3\u003eOverview\u003c\/h3\u003e\n  \u003cp\u003eKL-40MPCG is the green Santoprene TPV protective cap for a KUPO K-LOK 400 A inline male connector. It covers the exposed connector interface while the cable is disconnected and remains attached through a 299 mm lanyard assembly. The green body is suited to documented green identification schemes, while the dedicated fit supports NEMA 3R protection when correctly seated.\u003c\/p\u003e\n\n  \u003ch3\u003eWhy It Matters\u003c\/h3\u003e\n  \u003cp\u003eThe male end of a 400 A feeder remains exposed whenever a run is broken down, staged or moved between distribution points. A connector-specific cap helps keep rain, dust and handling debris away from that interface without becoming a loose accessory. The green finish also carries the cable-identification plan to the point crews handle first.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMale-Connector Fit:\u003c\/strong\u003e Purpose-shaped for the K-LOK 400 A inline male connector rather than used as a generic cable cover.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSantoprene TPV Construction:\u003c\/strong\u003e Flexible, durable material rated up to 105 °C tolerates repeated fitting and removal in touring and rental workflows.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTethered Retention:\u003c\/strong\u003e The 299 mm lanyard keeps the cap with its cable assembly through setup, operation and strike.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGreen Identification:\u003c\/strong\u003e Supports green-coded identification where assigned by the system.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eListed Performance:\u003c\/strong\u003e UL Enclosure Types 3R environmental rating with HB \/ UL94 flame class.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eApplications\u003c\/h3\u003e\n  \u003cp\u003eIntended for 400 A feeder cables used in touring power, rental inventories, generator connections, temporary distribution, industrial systems and outdoor event production.\u003c\/p\u003e\n\n  \u003ch3\u003eCompatibility\u003c\/h3\u003e\n  \u003cp\u003eFits KUPO K-LOK 400 A inline male connectors and compatible cam-type systems with the same interface. It is not interchangeable with the female-connector cap or the smaller 150 A protective-cap family.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-40MPCG - K-LOK 400 A Male Connector Protective Cap, Green\",\n  \"description\": \"KUPO KL-40MPCG green Santoprene TPV protective cap for a K-LOK 400 A inline male connector, with a 299 mm tether lanyard and NEMA 3R protection when correctly fitted.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO., LTD.\"\n  },\n  \"category\": \"Power Solution \u003e K-LOK Accessories\",\n  \"sku\": \"KL-40MPCG\",\n  \"mpn\": \"KL-40MPCG\",\n  \"color\": \"Green\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Product Type\",\n      \"value\": \"Tethered protective cap\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Series\",\n      \"value\": \"K-LOK 400 A\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fits\",\n      \"value\": \"Inline male connector\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Material\",\n      \"value\": \"Santoprene TPV\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environmental Protection\",\n      \"value\": \"Supports NEMA 3R when correctly fitted\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Temperature Rating\",\n      \"value\": \"Up to 105 °C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Green\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cap Length\",\n      \"value\": \"67 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Outer Diameter\",\n      \"value\": \"37.5 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Inner Diameter\",\n      \"value\": \"27 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Lanyard Assembly Length\",\n      \"value\": \"299 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Attachment Ring Diameter\",\n      \"value\": \"25.4 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Ferrule\",\n      \"value\": \"Adjustable; crimped by installer\"\n    }\n  ],\n  \"productID\": \"KL-40MPCG\"\n}\n\u003c\/script\u003e\n\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #2C3E50 !important;\n}\n.kupo-faq-seo-item { margin: 0 0 1.35rem 0; }\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #2C3E50 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-40MPCG\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eMay green be used for a protective-earth feeder set?\u003c\/h3\u003e\n    \u003cp\u003eIt can support a documented green identification system, but conductor function must always be verified from electrical markings and testing.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the matching green cap for the female connector?\u003c\/h3\u003e\n    \u003cp\u003eKL-40FPCG fits the 400 A inline female connector. KL-40MPCG is specifically shaped for the male side.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the cap help during outdoor staging?\u003c\/h3\u003e\n    \u003cp\u003eWhen correctly fitted, the Santoprene TPV body shields the disconnected male interface and supports NEMA 3R protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eDoes the tether need installer finishing?\u003c\/h3\u003e\n    \u003cp\u003eYes. The adjustable ferrule is positioned and crimped by the installer to retain the 299 mm lanyard.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"May green be used for a protective-earth feeder set?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It can support a documented green identification system, but conductor function must always be verified from electrical markings and testing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the matching green cap for the female connector?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"KL-40FPCG fits the 400 A inline female connector. KL-40MPCG is specifically shaped for the male side.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does the cap help during outdoor staging?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"When correctly fitted, the Santoprene TPV body shields the disconnected male interface and supports NEMA 3R protection.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the tether need installer finishing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. The adjustable ferrule is positioned and crimped by the installer to retain the 299 mm lanyard.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"KUPO Stage","offers":[{"title":"K-Lok \/ 400A \/ Accessory","offer_id":54065345003819,"sku":"KL-40MPCG","price":0.0,"currency_code":"TWD","in_stock":true}],"url":"https:\/\/kupostage.com\/products\/kl-40mpcg","provider":"KUPO Stage","version":"1.0","type":"link"}