{"product_id":"kl-dcb","title":"KL-DCB - K-LOK Dust Cover for 400 A Cam-Type Receptacle, Blue","description":"\u003c!-- Combined Shopify product HTML for KL-DCB --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #2C3E50 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #2C3E50 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-DCB\" data-color=\"Blue\"\u003e\n  \u003ch3\u003eOverview\u003c\/h3\u003e\n  \u003cp\u003eKL-DCB is the blue weatherproof snap-back cover for a compatible 400 A cam-type panel receptacle. A high-impact, flame-retardant ABS body, corrosion-resistant stainless-steel hardware and a supplied gasket form a durable closure for the unused receptacle. The standard 57.3 mm square frame supports retrofit installation, and the blue lid helps crews trace blue-coded receptacles across a distribution panel.\u003c\/p\u003e\n\n  \u003ch3\u003eWhy It Matters\u003c\/h3\u003e\n  \u003cp\u003ePanel receptacles may remain exposed through outdoor staging, transport and long periods between connections. The hinged lid stays attached to the enclosure and closes over the receptacle as soon as the feeder is removed, helping exclude falling rain, dust and debris. The blue finish keeps the circuit-identification cue visible directly at the connection point.\u003c\/p\u003e\n\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSnap-Back Closure:\u003c\/strong\u003e The hinged lid remains attached to the panel and covers the receptacle after cable removal.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGasketed NEMA 3R Protection:\u003c\/strong\u003e The supplied gasket helps resist falling rain and outdoor exposure when correctly installed.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRetrofit Frame:\u003c\/strong\u003e The standard 57.3 mm square frame and 38 mm mounting centers suit compatible 400 A cam-type receptacles.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBlue Identification:\u003c\/strong\u003e Supports blue-coded identification across temporary-power inventories.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eListed Performance:\u003c\/strong\u003e UL Enclosure Types 3R environmental rating with HB \/ UL94 flame class.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eApplications\u003c\/h3\u003e\n  \u003cp\u003eDesigned for 400 A cam-type receptacles on touring distros, generator panels, rental power equipment, industrial enclosures and temporary event-power systems.\u003c\/p\u003e\n\n  \u003ch3\u003eCompatibility\u003c\/h3\u003e\n  \u003cp\u003eFits compatible 400 A cam-type panel receptacles using the listed 57.3 mm frame and 38 x 38 mm mounting-center pattern. It is not interchangeable with the smaller circular KL-DCXX2 cover for 150 A receptacles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-DCB - K-LOK Dust Cover for 400 A Cam-Type Receptacle, Blue\",\n  \"description\": \"KUPO KL-DCB blue gasketed snap-back dust cover for a 400 A cam-type panel receptacle, with flame-retardant ABS construction, stainless-steel hardware and NEMA 3R protection.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO., LTD.\"\n  },\n  \"category\": \"Power Solution \u003e K-LOK Accessories\",\n  \"sku\": \"KL-DCB\",\n  \"mpn\": \"KL-DCB\",\n  \"color\": \"Blue\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Product Type\",\n      \"value\": \"Weatherproof snap-back receptacle cover\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fits\",\n      \"value\": \"Compatible 400 A cam-type panel receptacle\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Body Material\",\n      \"value\": \"High-impact, flame-retardant ABS\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Hardware\",\n      \"value\": \"Corrosion-resistant stainless steel\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Seal\",\n      \"value\": \"Gasket supplied\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environmental Seal\",\n      \"value\": \"NEMA 3R when correctly installed and closed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Blue\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Frame Size\",\n      \"value\": \"57.3 x 57.3 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Centers\",\n      \"value\": \"38 x 38 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Holes\",\n      \"value\": \"4 x 6.5 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Lid Diameter\",\n      \"value\": \"53 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Inner Opening\",\n      \"value\": \"45 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Overall Height\",\n      \"value\": \"50 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Body Height\",\n      \"value\": \"48.5 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Body Width\",\n      \"value\": \"47 mm\"\n    }\n  ],\n  \"productID\": \"KL-DCB\"\n}\n\u003c\/script\u003e\n\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #2C3E50 !important;\n}\n.kupo-faq-seo-item { margin: 0 0 1.35rem 0; }\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #2C3E50 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-DCB\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the snap-back lid help during changeovers?\u003c\/h3\u003e\n    \u003cp\u003eThe cover stays mounted to the panel, opens for the feeder connection and returns over the receptacle after disconnection, so no loose cap has to be stored.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich mounting pattern should be prepared for KL-DCB?\u003c\/h3\u003e\n    \u003cp\u003ePrepare four 6.5 mm fixing holes on 38 x 38 mm centers for the 57.3 x 57.3 mm frame.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy is flame-retardant ABS used for the blue lid?\u003c\/h3\u003e\n    \u003cp\u003eABS provides impact resistance for repeated field handling, while the flame-retardant formulation suits power-distribution equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat opening and lid diameters are shown for KL-DCB?\u003c\/h3\u003e\n    \u003cp\u003eThe catalog drawing lists a 45 mm inner opening and a 53 mm lid diameter.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does the snap-back lid help during changeovers?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The cover stays mounted to the panel, opens for the feeder connection and returns over the receptacle after disconnection, so no loose cap has to be stored.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which mounting pattern should be prepared for KL-DCB?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Prepare four 6.5 mm fixing holes on 38 x 38 mm centers for the 57.3 x 57.3 mm frame.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why is flame-retardant ABS used for the blue lid?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"ABS provides impact resistance for repeated field handling, while the flame-retardant formulation suits power-distribution equipment.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What opening and lid diameters are shown for KL-DCB?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The catalog drawing lists a 45 mm inner opening and a 53 mm lid diameter.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e\n","brand":"KUPO Stage","offers":[{"title":"K-Lok \/ 400A \/ Accessory","offer_id":54065345364267,"sku":"KL-DCB","price":0.0,"currency_code":"TWD","in_stock":true}],"url":"https:\/\/kupostage.com\/products\/kl-dcb","provider":"KUPO Stage","version":"1.0","type":"link"}