{"product_id":"pfpd-2r","title":"PFPD-2R - PowerFit 400 A Panel Drain, L2 (Phase B) Red (NEC - North American)","description":"\u003c!--Combined Shopify product HTML for PFPD-2R --\u003e\u003cstyle\u003e.kupo-section-title { margin: 1.25rem 0 1rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.3; color: #2C3E50 !important; letter-spacing: 0;}.product-description h3 { color: #2C3E50 !important; font-size: 18px !important; font-weight: bold; margin-top: 1.5rem; margin-bottom: 0.75rem; line-height: 1.35; letter-spacing: 0;}.product-description,.product-description p,.product-description li { color: #222222 !important;}.kupo-faq-seo-block { margin: 3rem 0 0 0; padding: 0; border: 0; background: transparent; box-sizing: border-box;}.kupo-faq-seo-block h2 { margin: 0 0 1.6rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.4; color: #2C3E50 !important;}.kupo-faq-seo-item h3 { margin: 0 0 0.35rem 0; font-size: 17px !important; font-weight: 600; line-height: 1.45; color: #2C3E50 !important;}.kupo-faq-seo-item p { margin: 0; line-height: 1.6; color: #222222 !important;}.kupo-download-section { margin: 2rem 0 0 0; padding: 0; border: 0; background: transparent; box-sizing: border-box;}.kupo-download-section h2 { margin: 0 0 1rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.4; color: #2C3E50 !important;}.kupo-download-link { display: inline-flex; align-items: center; gap: 0.4rem; font-size: 16px !important; line-height: 1.5; color: #111111 !important; font-weight: 600; text-decoration: underline;}\u003c\/style\u003e\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\u003c!-- PowerFit 400 A Panel Drain Connector (Red) | PFPD-2R | 2026-03-23 --\u003e\u003cdiv class=\"product-description\" data-sku=\"PFPD-2R\" data-color=\"Red\"\u003e \u003ch3\u003eOverview\u003c\/h3\u003e \u003cp\u003e Film and television production facilities operating under North American electrical code standards require permanent power infrastructure that delivers 400 A across secondary phase circuits to lighting rigs, camera equipment systems, and support infrastructure mounted in outdoor stages and soundstage electrical rooms. The PowerFit 400 A Panel Drain connector in red (Phase 2 \/ L2 NEC) provides the enclosure-mount architecture for secondary phase distribution in production facility switchboards, enabling rapid reconfiguration during multi-day shoot schedules while maintaining the structural integrity demanded by UL94-V0 rated thermoplastic construction. The patent key-release pin simplifies hot-swap maintenance operations, while the plastic end cap prevents accidental contact with live electrical surfaces during crowded equipment bay work.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e  \u003cul\u003e   \u003cli\u003e400 A continuous current rating at 120 mm² cable; 660 A at 240 mm² cable for multi-rig film production distribution\u003c\/li\u003e   \u003cli\u003e Fesource interface design ensures reliable mating with Panel Source connectors across consecutive shoot days\u003c\/li\u003e   \u003cli\u003eM12 threaded post with brass nut and spring washer provides secure fastening in soundstage cabinet installations\u003c\/li\u003e   \u003cli\u003e Four diameter 5.5 mm fixing holes (42 mm x 42 mm cut-out) accommodate standard North American electrical cabinet frames\u003c\/li\u003e   \u003cli\u003ePatent key-release pin enables production electricians to safely disconnect feeds between take configurations without tools\u003c\/li\u003e   \u003cli\u003ePlastic end cap over drain interface provides IP 2X finger protection in high-traffic production cable management areas\u003c\/li\u003e   \u003cli\u003ePush-and-twist locking mechanism resists accidental separation from equipment movement and vibration\u003c\/li\u003e   \u003cli\u003eSilver-plated brass contact delivers 0.1 mOhms contact resistance, minimizing voltage drop across extensive grid lighting systems\u003c\/li\u003e   \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets North American motion picture safety standards\u003c\/li\u003e   \u003cli\u003eIP67 rating while mated provides protection against water ingress from outdoor weather conditions and studio spray cooling systems\u003c\/li\u003e   \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure mounting without risk of rework during shoot schedules\u003c\/li\u003e   \u003cli\u003eRed color codes as Phase 2 (L2) under NEC, providing standard phase identification for North American production crews\u003c\/li\u003e  \u003c\/ul\u003e \u003ch3\u003eStandards\u003c\/h3\u003e \u003cp\u003eTÜV Rheinland certified (ID 1111303479) for North American production facility electrical systems; CE marking for international production equipment certification; RoHS and REACH compliant for environmental responsibility in production operations; UL94-V0 flame retardancy rating for motion picture safety standards; IP67 rating (dust-tight, submersion-resistant) suitable for outdoor stage and studio installations; 1000 V AC \/ 1500 V DC maximum operating voltage; 4500 V AC dielectric test; Short circuit rating: Up to 35.5 kA; insulation resistance greater than 5000 MOhms at 500 V AC; Working temperature range: 45 to 85 °C - stable across production facility temperature control ranges. Match standards and compliance requirements to the local electrical code before installation.\u003c\/p\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cp\u003eSuitable for film and television soundstage permanent switchboard installations serving multiple lighting and power grids, outdoor stage power distribution enclosures for concert touring and event production facilities, production support equipment distribution (air conditioning, water systems, safety equipment) in production villages, camera truck and mobile production facility power interconnection systems, lighting truck trailer permanent power distribution panels for multi-camera field shoots, studio generator paralleling switchboards for seamless power backup during live broadcast productions, and post-production facility power management for editing suites and audio mixing systems.\u003c\/p\u003e \u003ch3\u003e Compatibility\u003c\/h3\u003e  \u003cp\u003eThe PowerFit 400 A Panel Drain connector is compatible with major brands of single-pole power connector systems used in North American film and television production infrastructure. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source connector carries production-grade certifications and matches your facility power specifications. The color-coded red housing complies with NEC phase identification standards used throughout North American motion picture and broadcast industry electrical systems.\u003c\/p\u003e \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e  \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\u003ctr\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208 V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: # CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480 V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: # CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: # CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003e China \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: # CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e  \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208 V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480 V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{  \"@context\": \"https:\/\/schema.org\",  \"@type\": \"Product\",  \"name\": \"PFPD-2R | PowerFit 400 A Panel Drain, L2 (Phase B) Red (NEC - North American)\",  \"description\": \"KUPO PowerFit 400 A Panel Drain single-pole connector with red housing for NEC - North American power distribution systems. Drain interface, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400 A\/660 A, 1000 V AC \/ 1500 V DC maximum, TUV certified.\",  \"brand\": {    \"@type\": \"Brand\",    \"name\": \"KUPO\"  },  \"manufacturer\": {    \"@type\": \"Organization\",    \"name\": \"KUPO CO. LTD\",    \"url\": \"https:\/\/www.kupopower.com\"  },  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",  \"sku\": \"PFPD-2R\",  \"mpn\": \"PFPD-2R\",  \"color\": \"Red\",  \"material\": \"Thermoplastic, UL94-V0; Brass (silver-plated)\",  \"additionalProperty\": [    {      \"@type\": \"PropertyValue\",      \"name\": \"Current Rating\",      \"value\": \"400 A maximum\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Voltage Rating\",      \"value\": \"1000 V AC, 1500 V DC maximum\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Connector Style\",      \"value\": \"Panel mount\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Source \/ Drain\",      \"value\": \"Drain\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Color Coding\",      \"value\": \"Red (L2)\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Housing Material\",      \"value\": \"Thermoplastic, UL94-V0\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Contact Material\",      \"value\": \"Brass (silver-plated)\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Protection Rating\",      \"value\": \"IP67 when mated\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Compatibility\",      \"value\": \"Major single-pole power connectors\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Certification\",      \"value\": \"CE \/ TUV\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Termination\",      \"value\": \"M12 threaded post\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Panel Mount\",      \"value\": \"42 x 42 mm cut-out, 4 x 5.5 mm holes\"    }  ],  \"productID\": \"PFPD-2R\"}\u003c\/script\u003e\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2R\" data-category=\"PowerFit 400 A Connectors\"\u003e \u003ch2\u003e Frequently Asked Questions\u003c\/h2\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eWhat is PFPD-2R and where is it permanently installed?\u003c\/h3\u003e  \u003cp\u003ePFPD-2R is a KUPO PowerFit 400 A panel drain connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eWhat current and voltage ratings make PFPD-2R suitable for permanent distribution?\u003c\/h3\u003e  \u003cp\u003ePFPD-2R is rated for 400 amperes continuous with 120 mm² cable, scaling to 660 amperes with 240 mm² cable. The maximum voltage rating is 1000 V AC or 1500 V DC. The insulation resistance exceeds 5000 megaohms at 500 V AC, and the test voltage rating of 4500 V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eHow does the red color coding on PFPD-2R help identify L2 on the jobsite?\u003c\/h3\u003e  \u003cp\u003eRed marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Drain, the red color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eHow does PFPD-2R meet safety requirements for panel-mounted power distribution?\u003c\/h3\u003e  \u003cp\u003ePFPD-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003e Can PFPD-2R work alongside connectors from other brands in a distribution panel?\u003c\/h3\u003e  \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPD-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eWhat are the mounting requirements for PFPD-2R in a panel?\u003c\/h3\u003e  \u003cp\u003eInstalling PFPD-2R requires a 42 x 42 mm cutout in the enclosure panel. The connector mounts through four 5.5 mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0 mm flange width and 72.2 mm total depth, with a 37.0 mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\u003c\/p\u003e \u003c\/div\u003e\u003c\/section\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is PFPD-2R and where is it permanently installed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R is a KUPO PowerFit 400 A panel drain connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\"}}, {\"@type\": \"Question\", \"name\": \"What current and voltage ratings make PFPD-2R suitable for permanent distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R is rated for 400 amperes continuous with 120 mm² cable, scaling to 660 amperes with 240 mm² cable. The maximum voltage rating is 1000 V AC or 1500 V DC. The insulation resistance exceeds 5000 megaohms at 500 V AC, and the test voltage rating of 4500 V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\"}}, {\"@type\": \"Question\", \"name\": \"How does the red color coding on PFPD-2R help identify L2 on the jobsite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Drain, the red color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2R meet safety requirements for panel-mounted power distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"Can PFPD-2R work alongside connectors from other brands in a distribution panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPD-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What are the mounting requirements for PFPD-2R in a panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Installing PFPD-2R requires a 42 x 42 mm cutout in the enclosure panel. The connector mounts through four 5.5 mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0 mm flange width and 72.2 mm total depth, with a 37.0 mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\"}}]}\u003c\/script\u003e\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2R\"\u003e \u003ch2\u003eDownload\u003c\/h2\u003e \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2R.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e  Download PFPD-2R Spec Sheet (PDF) \u003c\/a\u003e\u003c\/section\u003e","brand":"KUPO Stage","offers":[{"title":"PowerFit \/ 400A \/ Panel Drain","offer_id":53907617022251,"sku":"PFPD-2R","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/6887\/6843\/files\/PFPD-2R_b.jpg?v=1782112208","url":"https:\/\/kupostage.com\/products\/pfpd-2r","provider":"KUPO Stage","version":"1.0","type":"link"}