{"product_id":"pfps-2r","title":"PFPS-2R - PowerFit 400 A Panel Source, L2 (Phase B) Red (NEC - North American)","description":"\u003c!--Combined Shopify product HTML for PFPS-2R --\u003e\u003cstyle\u003e.kupo-section-title { margin: 1.25rem 0 1rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.3; color: #2C3E50 !important; letter-spacing: 0;}.product-description h3 { color: #2C3E50 !important; font-size: 18px !important; font-weight: bold; margin-top: 1.5rem; margin-bottom: 0.75rem; line-height: 1.35; letter-spacing: 0;}.product-description,.product-description p,.product-description li { color: #222222 !important;}.kupo-faq-seo-block { margin: 3rem 0 0 0; padding: 0; border: 0; background: transparent; box-sizing: border-box;}.kupo-faq-seo-block h2 { margin: 0 0 1.6rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.4; color: #2C3E50 !important;}.kupo-faq-seo-item h3 { margin: 0 0 0.35rem 0; font-size: 17px !important; font-weight: 600; line-height: 1.45; color: #2C3E50 !important;}.kupo-faq-seo-item p { margin: 0; line-height: 1.6; color: #222222 !important;}.kupo-download-section { margin: 2rem 0 0 0; padding: 0; border: 0; background: transparent; box-sizing: border-box;}.kupo-download-section h2 { margin: 0 0 1rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.4; color: #2C3E50 !important;}.kupo-download-link { display: inline-flex; align-items: center; gap: 0.4rem; font-size: 16px !important; line-height: 1.5; color: #111111 !important; font-weight: 600; text-decoration: underline;}\u003c\/style\u003e\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\u003c!-- PowerFit 400 A Panel Source Connector (Red) | PFPS-2R | 2026-03-23 --\u003e\u003cdiv class=\"product-description\" data-sku=\"PFPS-2R\" data-color=\"Red\"\u003e \u003ch3\u003eOverview\u003c\/h3\u003e \u003cp\u003eNorth American three-phase systems under NEC standards use red to identify the L2 (Phase B) conductor. The PowerFit 400 A Panel Source in red serves as the fixed-panel power inlet for generator connection boxes, portable power distribution units, and entertainment industry dimmer racks where 400 A per phase is standard. The M12 threaded post mount with brass nut and spring washer provides vibration-resistant panel attachment, and the 42 mm x 42 mm cut-out dimension with four diameter 5.5 mm fixing holes matches standard industrial panel preparation specifications.\u003c\/p\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e  \u003cul\u003e   \u003cli\u003e400 A continuous current capacity at 120 mm² cable; 660 A continuous at 240 mm² cable for heavy-duty applications\u003c\/li\u003e   \u003cli\u003eSource interface design provides the power source pin for mating with Line Drain or Panel Drain connectors\u003c\/li\u003e   \u003cli\u003ePatent key-release pin with POM (Polyoxymethylene) cotter pin enables tool-free disconnection without risking contact damage\u003c\/li\u003e   \u003cli\u003eM12 threaded post with brass nut and spring washer for permanent, vibration-resistant panel installation\u003c\/li\u003e   \u003cli\u003e Four diameter 5.5 mm fixing holes on flange (42 mm x 42 mm cut-out dimension) ensure secure mechanical mounting\u003c\/li\u003e   \u003cli\u003ePlastic end cap over source interface provides IP 2X finger protection against electric shock when unmated\u003c\/li\u003e   \u003cli\u003ePush-and-twist locking mechanism maintains positive mechanical engagement across 500 rated mating cycles\u003c\/li\u003e   \u003cli\u003eBrass contact with silver plating delivers 0.1 mOhms contact resistance for minimal voltage drop and heat generation\u003c\/li\u003e   \u003cli\u003eNon-conductive thermoplastic housing rated UL94-V0 flame retardant for safety-critical installations\u003c\/li\u003e   \u003cli\u003eIP67 rating when mated ensures protection against water and dust ingress in outdoor or washdown environments\u003c\/li\u003e   \u003cli\u003e1000 V AC \/ 1500 V DC maximum voltage rating with 4500 V AC dielectric test voltage for substantial safety margins\u003c\/li\u003e   \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter for proper fastening without over-tightening\u003c\/li\u003e  \u003c\/ul\u003e \u003ch3\u003eStandards\u003c\/h3\u003e \u003cp\u003eTUV Rheinland certified (ID 1111303479) - Type Approved, Safety, Regular Production Surveillance; CE marked for European market compliance; RoHS (Restriction of Hazardous Substances) compliant; REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) compliant; UL94-V0 flame retardancy classification for the housing material; IP67 environmental protection rating while mated (dust-tight, resistant to temporary submersion); Short circuit capacity: Up to 35.5 kiloamperes; Insulation resistance: Greater than 5000 MOhms at 500 V AC; Working temperature range: 45 to 85 °C. Match standards and compliance requirements to the local electrical code before installation.\u003c\/p\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cp\u003eSuitable for three-phase power distribution panels requiring dedicated L2 phase inlets, dimmer rack and lighting control enclosures for theatrical and concert touring systems, industrial manufacturing equipment with balanced three-phase power requirements, power management systems for mining and heavy industry operations, UPS (Uninterruptible Power Supply) bypass panels and transfer switch enclosures, festival and outdoor event power distribution boards with weather-exposed installations, and generator paralleling switchboards requiring per-phase connection management.\u003c\/p\u003e \u003ch3\u003e Compatibility\u003c\/h3\u003e  \u003cp\u003eThe PowerFit 400 A Panel Source connector is compatible with major brands of single-pole power connector systems. Its M12 threaded post interface and push-and-twist mating mechanism with key-release pin ensure standardized connection geometry across certified suppliers. The source interface mates with PowerFit Line Drain and Panel Drain connectors. Verify mechanical and electrical specifications with your mating connector manufacturer to check impedance matching and safe operating parameters. Use the color-coded and mechanically keyed design as a visual safeguard to prevent cross-phase connection errors during installation or reconfiguration.\u003c\/p\u003e \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e  \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\u003ctr\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208 V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: # CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480 V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: # CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: # CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003e China \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: # CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e  \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208 V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480 V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{  \"@context\": \"https:\/\/schema.org\",  \"@type\": \"Product\",  \"name\": \"PFPS-2R | PowerFit 400 A Panel Source, L2 (Phase B) Red (NEC - North American)\",  \"description\": \"KUPO PowerFit 400 A Panel Source single-pole connector with red housing for NEC - North American power distribution systems. Source interface, M12 threaded post mount, patent key-release pin for safe disconnection, IP67 rated when mated, silver-plated brass contacts, dual-rated 400 A\/660 A, 1000 V AC \/ 1500 V DC maximum, TUV certified.\",  \"brand\": {    \"@type\": \"Brand\",    \"name\": \"KUPO\"  },  \"manufacturer\": {    \"@type\": \"Organization\",    \"name\": \"KUPO CO. LTD\",    \"url\": \"https:\/\/www.kupopower.com\"  },  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",  \"sku\": \"PFPS-2R\",  \"mpn\": \"PFPS-2R\",  \"color\": \"Red\",  \"material\": \"Thermoplastic, UL94-V0; Brass (silver-plated)\",  \"additionalProperty\": [    {      \"@type\": \"PropertyValue\",      \"name\": \"Current Rating\",      \"value\": \"400 A maximum\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Voltage Rating\",      \"value\": \"1000 V AC, 1500 V DC maximum\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Connector Style\",      \"value\": \"Panel mount\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Source \/ Drain\",      \"value\": \"Source\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Color Coding\",      \"value\": \"Red (L2)\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Housing Material\",      \"value\": \"Thermoplastic, UL94-V0\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Contact Material\",      \"value\": \"Brass (silver-plated)\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Protection Rating\",      \"value\": \"IP67 when mated\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Compatibility\",      \"value\": \"Major single-pole power connectors\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Certification\",      \"value\": \"CE \/ TUV\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Termination\",      \"value\": \"M12 threaded post\"    },    {      \"@type\": \"PropertyValue\",      \"name\": \"Panel Mount\",      \"value\": \"42 x 42 mm cut-out, 4 x 5.5 mm holes\"    }  ],  \"productID\": \"PFPS-2R\"}\u003c\/script\u003e\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2R\" data-category=\"PowerFit 400 A Connectors\"\u003e \u003ch2\u003e Frequently Asked Questions\u003c\/h2\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eWhat is PFPS-2R and why is it the starting point of power distribution?\u003c\/h3\u003e  \u003cp\u003ePFPS-2R is a KUPO PowerFit 400 A panel source connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eWhat are the power handling specifications of PFPS-2R?\u003c\/h3\u003e  \u003cp\u003ePFPS-2R is rated for 400 amperes continuous with 120 mm² cable, scaling to 660 amperes with 240 mm² cable. The maximum voltage rating is 1000 V AC or 1500 V DC. The insulation resistance exceeds 5000 megaohms at 500 V AC, and the test voltage rating of 4500 V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eWhat does the red housing on PFPS-2R represent under North America (NEC) standards?\u003c\/h3\u003e  \u003cp\u003eRed marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Source, the red housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eHow is PFPS-2R certified for use as a power source connector?\u003c\/h3\u003e  \u003cp\u003ePFPS-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003eWhat makes PFPS-2R installation straightforward for permanent power sources?\u003c\/h3\u003e  \u003cp\u003eThe PFPS-2R mounts through a 42 x 42 mm panel cutout using four 5.5 mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2R retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3 mm flange width and 50.7 mm total depth, with a 42.5 mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e  \u003ch3\u003e Can PFPS-2R work alongside connectors from other brands in a distribution panel?\u003c\/h3\u003e  \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPS-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e \u003c\/div\u003e\u003c\/section\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is PFPS-2R and why is it the starting point of power distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R is a KUPO PowerFit 400 A panel source connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\"}}, {\"@type\": \"Question\", \"name\": \"What are the power handling specifications of PFPS-2R?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R is rated for 400 amperes continuous with 120 mm² cable, scaling to 660 amperes with 240 mm² cable. The maximum voltage rating is 1000 V AC or 1500 V DC. The insulation resistance exceeds 5000 megaohms at 500 V AC, and the test voltage rating of 4500 V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFPS-2R represent under North America (NEC) standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Source, the red housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2R certified for use as a power source connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\"}}, {\"@type\": \"Question\", \"name\": \"What makes PFPS-2R installation straightforward for permanent power sources?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFPS-2R mounts through a 42 x 42 mm panel cutout using four 5.5 mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2R retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3 mm flange width and 50.7 mm total depth, with a 42.5 mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\"}}, {\"@type\": \"Question\", \"name\": \"Can PFPS-2R work alongside connectors from other brands in a distribution panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPS-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2R\"\u003e \u003ch2\u003eDownload\u003c\/h2\u003e \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2R.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e  Download PFPS-2R Spec Sheet (PDF) \u003c\/a\u003e\u003c\/section\u003e","brand":"KUPO Stage","offers":[{"title":"PowerFit \/ 400A \/ Panel Source","offer_id":53907618791723,"sku":"PFPS-2R","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0999\/6887\/6843\/files\/PFPS-2R_b.jpg?v=1782112231","url":"https:\/\/kupostage.com\/products\/pfps-2r","provider":"KUPO Stage","version":"1.0","type":"link"}